6010vet Veterinary High-Precision Continuous Infusion Pump
- Point of origin
- China CE ISO13485 ISO9001
- Throughput
- 0.1-1200.0ml/h
- Application scenarios
- veterinary Clinical,hospital
- Sample
- Cats, dogs, pigs.....
6010vet Infusion Pump
6010VET veterinary infusion pump is a high-precision continuous infusion equipment that meets the need for precise control of speed and dosage during long-term infusion. It integrates intelligent functions to make operation easier and safety performance is greatly enhanced. The design of the independent motor drive CPU and subdivision drive chip ensures the precision and accuracy of the infusion action. Equipped with infusion pole fixing plate, barcode scanner, WIFI communication module, voice call, nurse call and other functional options. The wireless WIFI networking function can be connected to the intravenous infusion central station to achieve remote monitoring and management.
key features of 6010vet
| product name | infusion pump |
| mode | 6010 VET |
| power supply | AC power supply: AC 100-240V 50/60Hz input power 45VA External DC power supply: DC 12V Built-in battery: lithium battery 7.2V 2600mAh; Model: 18650-2S1P-02; Continuous use time is not less than 5 hours (when the new battery is fully charged and infused at a speed of 25m1/h) |
| Suitable infusion set | All disposable infusion sets that meet standards |
| Infusion mode | Speed mode, time mode, weight mode, sequence mode, drip mode |
| Infusion speed range | 0.1-1200m1/h |
| Preset amount setting range | 0.10 -99.99m1 (minimum increment 0.01) 100- 999.9m1 (minimum increment 0.1) 1000-9999m1 (minimum increment 1) |
| Infusion accuracy | soil 5% |
| Exhaust operation | 1200mL/h |
| Fast forward operation | 0.10-1200m1/h |
| KV0 speed | 0.10-5.00mL/h |
| Anti-Bolus | Support Anti-Bolus function; pill dosage ≤1.0m1 |
| single bubble | Bubble alarm accuracy: ±15u1 or ±20%, whichever is greater. Bubble level: 25,50,100,200,300,500,800(u1) |
| Accumulated bubbles | Accumulated bubble bubble level: 100u1/15min, 200u1/15min, 400u1/15min, 500u1/15min, 600u1/15min, 800u1/15min, 1000u1/15min |
| blocking level | 300mmHg~900mmHg, level 3 optional |
| Call the police | The infusion is about to be completed, the infusion is completed, the infusion is blocked, the battery is low, the battery is exhausted, there is no battery, there is no external power supply, the pump door is open, there are bubbles in the pipeline, there is no drop number sensor, there is no drip, the number of drops is abnormal, and there is forgetting. Operation, standby end, congestion warning. |