Veterinary Coagulation Analyzer NX-102

Veterinary Coagulation Analyzer NX-102
Veterinary Coagulation Analyzer NX-102
Veterinary Coagulation Analyzer NX-102
NX-102
Point of origin
China CE ISO13485
Testing item
PT/INR,APTT,TT,FIB,ACT
Throughput
30T/H
Application scenarios
veterinary hospital ;pet ICU ;animal clinic

The Veterinary Coagulation Analyzer NX-102 is a portable, reliable, and efficient tool designed for veterinary diagnostics. Here are the key points summarizing its features and applications:

Key Features:

  1. Portability:

    • Small Footprint: Weighs only 2 lbs, making it highly portable.

    • Rechargeable Battery: Can be used in various settings without the need for a constant power supply.

  2. Convenience:

    • One-step Process: No additional accessories required, simplifying the testing process.

    • Maintenance-free: Designed to be maintenance-free, reducing operational costs and effort.

  3. Fast and Reliable:

    • Rapid Results: Provides results in 3 minutes or less.

    • Precision: Coefficient of Variation (CV) ≤ 5%, ensuring reliable and consistent results.

Applications:

  1. Screening Tests:

    • Exogenous and Endogenous Coagulation System: Assesses the function of coagulation systems in canines and felines.

  2. Monitoring:

    • Anticoagulant Treatment: Ensures the effectiveness and safety of anticoagulant therapy.

    • Thrombolytic Therapy: Monitors the efficacy of thrombolytic treatments.

    • Certain Diseases: Tracks coagulation status in patients with conditions such as hepatopathy, infections, and burn injuries.

  3. Tests Supported:

    • PT/INR (Prothrombin Time/International Normalized Ratio)

    • APTT (Activated Partial Thromboplastin Time)

    • TT (Thrombin Time)

    • FIB (Fibrinogen)

    • ACT (Activated Clotting Time)

  4. Sample Requirements:

    • Sample Type: Citrated venous whole blood or capillary blood (PT/INR only).

    • Sample Volume: 20 μL.

  5. Performance:

    • Time to Result: 5 minutes.

    • Precision: CV ≤ 5%.

    • Storage: Reagents are valid for 18 months at room temperature.

ltems Sample Types Sample SizeReference Range
PTWhole Blood20uLC anine: 5-15sFeline: 6-1 5s
NRWhole Blood20uLC anine: 0.5-1.6Feline: 0.6-1.6
APT TWhole Blood20pLC anine: 15-45sFeline:15-43s
TTWhole Blood20pLC anine: 8-20sFeline: 9-22s
FIBWhole Blood20uLCanine: 1-3g/LFeline: 1-2.5g/L
AC;TWhole Blood20uLC anine: 50-1 50sFeline: 50-1 60sL


人用优惠活动1.jpg

The Veterinary Coagulation Analyzer NX-102, with its ability to perform PT/INR, APTT, TT, FIB, and ACT tests, is a versatile and essential tool in veterinary practice, providing rapid, reliable, and precise diagnostics for a wide range of clinical applications.


Veterinary Clinics and Hospitals:

  • Routine coagulation screening for various animals.

  • Monitoring of anticoagulant and thrombolytic therapies.

  • Pre-surgical screening to ensure safe surgical outcomes.

1. Prothrombin Time/International Normalized Ratio (PT/INR)

Clinical Applications:

  • Anticoagulant Therapy Monitoring: Regularly used to monitor patients on warfarin therapy to ensure proper dosing and prevent complications like bleeding or thrombosis.

  • Liver Function Assessment: PT/INR can indicate liver disease, as the liver synthesizes clotting factors. Elevated PT/INR suggests impaired liver function.

  • Coagulation Disorders: Used to diagnose bleeding disorders such as hemophilia, von Willebrand disease, and other factor deficiencies.

  • Pre-Surgical Screening: Assesses the coagulation status before surgical procedures to minimize bleeding risks.

2. Activated Partial Thromboplastin Time (APTT)

Clinical Applications:

  • Heparin Therapy Monitoring: Essential for monitoring patients receiving unfractionated heparin to adjust dosage and avoid complications.

  • Coagulation Factor Deficiencies: Helps diagnose deficiencies in intrinsic pathway factors such as factors VIII, IX, XI, and XII.

  • Lupus Anticoagulant Testing: Elevated APTT may indicate the presence of lupus anticoagulant, an autoimmune disorder.

  • Pre-Surgical Screening: Used to evaluate bleeding risk before surgeries, especially in patients with known or suspected coagulation disorders.

3. Thrombin Time (TT)

Clinical Applications:

  • Fibrinogen Function: Assesses the final step of the coagulation process, where fibrinogen is converted to fibrin by thrombin. Prolonged TT indicates issues with fibrinogen function.

  • Heparin Presence: Prolonged TT can indicate the presence of heparin or direct thrombin inhibitors in the blood.

  • Dysfibrinogenemia: Identifies qualitative abnormalities of fibrinogen, which can be inherited or acquired.

4. Fibrinogen (FIB)

Clinical Applications:

  • Assessing Clot Strength: Fibrinogen levels directly affect the strength and stability of clots. Low levels indicate an increased risk of bleeding.

  • Disseminated Intravascular Coagulation (DIC): Used to diagnose and monitor DIC, a condition characterized by widespread clotting and bleeding.

  • Liver Disease and Inflammatory States: Evaluates liver function and acute phase reactions, as fibrinogen is a liver-synthesized acute-phase protein.

  • Cardiovascular Risk: Elevated fibrinogen levels are associated with an increased risk of cardiovascular diseases.

5. Activated Clotting Time (ACT)

Clinical Applications:

  • Heparin Monitoring during Procedures: Primarily used during surgeries requiring high doses of heparin, such as cardiopulmonary bypass or dialysis, to ensure effective anticoagulation.

  • Rapid Assessment in Emergency Situations: Provides quick evaluation of the coagulation status in trauma patients or during critical care.

  • Point-of-Care Testing: Convenient for bedside or intraoperative monitoring of anticoagulation status.


×
Send RFQ,Special Pricing Available
  • First Name *
  • Last Name *
  • Email *
  • Phone Number/WhatsApp *
  • Interest Products
  • Country *
  • Dealer/Terminal
  • Message *