2-8 ℃ Pharmacy Refrigerator Medical normal temperature reagent low temperature refrigerator 56L-1500L

2-8 ℃ Pharmacy Refrigerator Medical normal temperature reagent low temperature refrigerator 56L-1500L
2-8 ℃ Pharmacy Refrigerator Medical normal temperature reagent low temperature refrigerator 56L-1500L
2-8 ℃ Pharmacy Refrigerator Medical normal temperature reagent low temperature refrigerator 56L-1500L
2-8 ℃ Pharmacy Refrigerator Medical normal temperature reagent low temperature refrigerator 56L-1500L
2-8 ℃ Pharmacy Refrigerator Medical normal temperature reagent low temperature refrigerator 56L-1500L
56L-1500L
Point of origin
China CE ISO13485 ISO9001
Application scenarios
lab,science,hospital,Undercounter,CDC
Sample
drugs/reagents

Place of Origin

China

Model Number

56-1500L

Instrument classification

Class II

Warranty

2 years

After-sale Service

Online technical support

Product Name

Pharmacy Refrigerator

Capacity

56L

Control System

LED Digital Display

Temperature Range

2-8 ℃ 

Refrigeration Type

Forced Air Refrigeration System

Type

Glass door/Solid door

Certificate

CE/ISO 9001 13485


Structure Design 

· Double-pane glass door with electric heating function can against condensation at 16-32 ℃ ambient temperature. Also, it is self-closing in case the samples are  damaged due to user’s forgetting to close the door; 

· The internal material is sprayed aluminum plate (optional stainless steel), which is durable and easy-to-clean; 

· Removable shelves inside the refrigerator compartment are available for flexible storage solutions and these wire shelves remain stable temperatures wherever  products are stored, even in a fully loaded chamber; 

· Each shelf is equipped with a label holder, which can record sample information, so that users can select the desired samples easily and quickly. 


Refrigeration system 

· Air circulation with finned evaporator achieves fast cooling and ensures temperature uniformity in the cabinet ; 

· Industrial compressor with hydrocarbon refrigerant realizes energy conservation and environmental protection; 

· HC refrigerant with ultra low GWP minimize thermal radiation, meanwhile to reduce HVAC energy consumption. 


Control system 

· Microprocessor controller can display temperature in 0.1°C increments; 

· An access port (∅25mm) is convenient to connect monitoring /testing/ back-up device;

· Multiple audible and visible alarm system;  

 The RS485 interface is capable of defining and transferring critical temperature data of the equipment by the MODBUS protocol


×
Send RFQ,Special Pricing Available
  • First Name *
  • Last Name *
  • Email *
  • Phone Number/WhatsApp *
  • Interest Products
  • Country *
  • Dealer/Terminal
  • Message *