Getein1100 POCT Immunofluorescence analyzer

Getein1100 POCT Immunofluorescence analyzer
Getein1100
Point of origin
FSC CE NMPA NGSP IFCC
Testing item
cTnl NT-proBNP CK-MB/cTnI/Myo H-FABP * CK-MB/cTnI/H-FABP*
Throughput
3-15min
Application scenarios
clinic,hospital,lab

Getein 1100 immunofluorescence quantitative analyzer is becoming a new star in the field of medical diagnosis with its efficient detection speed, accurate result output and user-friendly operating experience. Its design concept and technical implementation not only improve the efficiency of diagnosis, but also greatly improve the quality of medical services, providing strong support for the early detection and management of diseases.


Assay MethodLateral flow chromatography (Immunofluorescence)
Test ResultQuantitative
LanguageEnglish/Chinese
Display7 inch touch screen
PrinterInternal thermal printer

Temperature:+15 C-35 C
Working EnvironmentHumidity: 10%-85%

Air pressure: 70.0 kPa-106.0 kPa
Power SupplyAC100 V-AC240 V, 50 Hz-60 Hz, 60 VA
Storage Capacity10,000 data (Max)
Dimensions261 mmx241 mmx115 mm (DxWxH)
Weight1.9 kg



Getein 1100 Immunofluorescence Quantitative Analyzer - a fast, accurate and convenient diagnostic tool.


1. Advanced technology and accurate results

Getein 1100 immunofluorescence quantitative analyzer uses leading fluorescence immunoassay technology, combined with multiple quality controls, to ensure the efficiency and accuracy of test results. The application of this technology allows the instrument to provide reliable data in just 5 seconds when conducting multi-item tests, greatly saving the waiting time of doctors and patients.


2. Humanized design, easy to operate

The device is equipped with a 7-inch touch screen, and the interface is intuitive and easy to understand, making the operation more user-friendly. The built-in and external modes based on the Android system can be selected according to the needs of different customers to meet diverse usage scenarios. The special code scanning recognition function makes automatic printing and uploading of data simple and fast.


3. Real-time testing, quick results

The Getein 1100 immunofluorescence quantitative analyzer supports real-time testing, and the time from sampling to obtaining results is only about 2-15 minutes, which is of great significance for clinical decision-making in emergency situations. Rapid result feedback can guide doctors to the next treatment plan in a timely manner.


4. Portable design, adaptable to various environments

This point-of-care diagnostic device is small in size, light in weight, and has built-in lithium battery support, allowing it to operate stably in a variety of environments, whether in the hospital's emergency room, ward, or outdoor mobile medical services. performance.


5. Comprehensive testing with wide coverage

Getein 1100 immunofluorescence quantitative analyzer provides more than 10 supporting reagents, covering disease management in many important fields such as heart, inflammation, renal function, and diabetes care. Such comprehensive detection capabilities make it a powerful assistant for doctors in clinical diagnosis.

2].jpg

cTnlMyocardial infarction0.10 ng/mLS/P/WB
TnTMyocardial infarction14.0 pg/mLS/P/WB
BNPHeart failure100.0 pg/mLP/WB
NT-proBNPHeart failure300 pg/mLS/P/WB
CK-MB/cTnI/MyoMyocardial damage /infarctionCK-MB: 5.00 ng/mL cTnl: 0.10 ng/mL Myo: 70.0 ng/mLS/P/WB
CK-MB/cTnlMyocardial damage /infarctionCK-MB: 5.00 ng/mL cTnl: 0.10 ng/mLS/P/WB
H-FABPMyocardial damage6.36ng/mLS/P/WB
CK-MB/cTnI/H-FABPMyocardial damage /infarctionCK-MB: 5.00 ng/mL cTnl: 0.10 ng/mL H-FABP: 6.36 ng/mLS/P/WB
CK-MB Myocardial injury  5.00 ng/mLS/P/WB
D-DimerVenous thromboembolism0.50 mg/LP/WB
hs-CRP+CRP Cardiovascular inflammation/normal inflammation 3.0 mg/L
10.0 mg/L 
S/P/WB/Fingertip blood
PCTSepsis, bacterial infection0.10ng/mLS/P/WB
PCT/CRPSepsis, bacterial infectionPCT:0.10ng/mL CRP: 3.0 mg/LS/P/WB
SAABacterial/Virus infection10.0 mg/LS/P/WB/ Fingertip blood
SAA/CRPNeonatal sepsis, Bacterial/virus infectionSAA: 10.0 mg/L CRP: 10.0 mg/LS/P/WB/ Peripheral blood
IL-6Acute inflammation  7.0 pg/mLS/P/WB/ Peripheral blood
CysCAcute and chronic renal diseases0.51-1.09 mg/LS/P/WB
mAlbDiabetic nephropathy, hypertensive nephropathy20.0 mg/LUrine
NGALAcute kidney injurySerum: 200.0 ng/mL Urine: 100.0 ng/mLS/Urine
B,-MGAcute and chronic kidney diseases/tumours0.80-3.00 mg/LS/P/WB
HbAlcDiabetes mellitus3.80%-5. .80%WB
Metabolic Marker 25-0H-VDOsteomalacia, osteoporosis30.00-50.00 ng/mLS/P
TSHThyroid malfunction0.27-4.20 pulU/mLS/P
T3Hyperthyroidism, hypothyroidism1.30-3.10nmol/LS/P
T4Hyperthyroidism, hypothyroidism59.00-154.00nmol/LS/P
fT3Hyperthyroidism, hypothyroidism3.10-6.80 pmol/LS/P/WB
fT4  Hyperthyroidism, hypothyroidism12.00-22.00 pmol/LS/P/WB
HCG+BFertility5.1 mIU/mLS/P
L .HPCOS, infertility evaluation Refer to User ManualS/P
FSHPCOS, infertility evaluation and pituitary disordersRefer to User ManualS/P
AMHFertility, PCOS, gonadal functior
precocious/late puberty
 Refer to User ManalS/P
PRLInfertility, gonadal disorders Refer to User ManualS/P
ProgInfertility, evaluation of ovulation Refer to User ManualS/P
Testosteronemale testosterone inuficiencyFemale polycystic ovary syndrome, Male: 1.75-7.81 ng/mL Female: 0.10-0.75 ng/mLS/P
E2 Ovarian function  Refer to User ManualS/P
For more test items please send a request to get the catalog


×